Menu

Question: 2.7.02-204

3 Points

Licenses: C C1 D D1 T C1E D1E DE

What can cause the air compressor in a braking system with a multi-circuit safety valve to deliver compressed air continuously?

Choose one or multiple correct answers
  • A. Piston wear in the air compressor has reached the stage where the cut-off pressure is no longer reached
  • B. A compressed air circuit connected to the multi-circuit safety valve is leaking
  • C. The multi-circuit safety valve is not switching off

Most students learn on the ClickClickDrive app. It is available for Android and iOS.

Theory App

Correct answer

  • A. Piston wear in the air compressor has reached the stage where the cut-off pressure is no longer reached
  • B. A compressed air circuit connected to the multi-circuit safety valve is leaking
Attachment

Comment

If the air compressor promotes continuously compressed air is the cause, that a connected to the multi-circuit protection valve pneumatic circuit has become leaking and the air compressor piston wear has progressed so far that the switch-off is no longer achieved.

Fault detection, localisation of faults

Chapter 2.7.02

Choose the language